Physical data:

  • Size: 8 x 6 metres (48 M2)
  • Weight: 24 Kg
  • Application: ICO, Electric & Hybrid Vehicles up to SUV size
  • Storage: Waterproof holdall bag with carrying handles

Please note: Being a UK manufacturer brings so many benefits to our customers. Our Fire Cloak™ Electric Vehicle Fire Blanket is made right here in the UK and that gives us the ability to provide a truly bespoke made-to-measure service for our customers. So whatever size fire blanket you need to protect against Lithium Battery fires we can make a Fire Cloak™ to suit your specific size requirements.

Technical data:

Material: Silica Quartz Fabric treated with Fire Retardant Coating

Property Description Value Tolerance Test Standard
Fabric Weight 475gsm ± 10% EN 12127
Tensile Strength (typical) Warp
Weft
4800 N/5cm
3700 N/5cm
± 5%
± 5%
ISO 4606
Electrical Burner Test M0 EN 13501
Fabric Melting Point >800°C
Reaction to Fire* B-s1, d0 EN 13501-1:2007 + A1:2009
Material Fire Test** Class 0 BS 476, Part 6+7
Fire Resistance*** Intertek Test Up to 1,000°C Non-Available
Hydrocarbon Resistance Rating Number: 7 BS EN ISO 14419: 2010
Hydrostatic Pressure Test Waterproof 492cm/H2O (Mbar) BS EN 20811: 1992 / ISO 811

*Reaction to Fire: Based on information assimilated from the fabric manufacturers technical database, definitive ISO testing is currently in progress (as at 03/12/2021).

**Material Fire Test: Based on information assimilated from the fabric manufacturers technical database, definitive ISO testing is currently in progress (as at 03/12/2021).

***Fire Resistance Testing: Samples were submitted to Intertek® and furnace testing to 800°C was conducted. The material, whilst compromised, retained is structure and was deemed effective for the intended purpose.

NOTE: Whilst EV fires can reach core temperatures exceeding 1,300°C, the surface temperature of the vehicle body will be much lower than this. Once deployed the EV Car Fire Blanket reduces temperature rapidly by depriving the fire of Oxygen. This allows the EV Car Fire Blanket to perform effectively within its fire resistance ratings.